Cooling SPEC's for common SCT and Pixel ID of ATLAS Prepared by Vic V. & Pierre B.
Refrigerant  -  C3F8
    Total Number of Staves Power per Modul Modules per Stave Power per Stave Mass Flow per Stave Stave per pipe Power at Layers Staves  Sub_T Total Power to cool down [W] Total Power to cool down [kW]
Structure:   [-] [W] [-] [W] [10-3.kg/s] IN [-] OUT [-] [W] PIXELS 58644.0 58.6
  PIXEL  "B", 1 Layer 18 10.3 13 133.9   1 1 2410.2 12220.0 PIXELS  
Barrels PIXEL, 2 Layers[42+56] 98 7.7 13 100   2/1 in series 4[2+2] / 1 pipe 9809.8 SCT 17764.0 17.8
  SCT, 4 Layers 176 10 12 120   2/1 in series 4[2+2] / 1 pipe 21120.0 21120.0 SCT  
 
TOTAL PIXEL 1508 33340.0 33340.0 40880.0 40.9
SCT 2112
    Total Number of wheels Power per Modul Modules per Wheel Number of Sectors Power per Sector Mass Flow per Sector Sector per pipe Power at Layers  Wheels         Sub_T
Structure:   [-] [W] [-] [-] [W] [10-3.kg/s] IN [-] OUT [-] [W] PIXELS
  PIXEL 10 7.7 72 12 46.2       5544.0 5544.0 5.5
  Wheels [Discs] SCT1_ [5+5] 10 10 132 8 165       13200.0 SCT
  SCT2_[3+3] 6 10 92 8 115       5520.0 19760.0 19.8
  SCT3_[1+1] 2 10 52 8 65       1040.0  
TOTAL PIXEL 720 25304.0 25304.0 25.3
SCT 1976