ATLAS Silicon Tracker

Evaporative Cooling System

 

G. Hallewell RAL/CPPM

 

Version 1.1 January 16, 2000

Refers to ATLAS Services Inventory ATL-IC-EN-005

(created 01.03.00, modified 27.06.00)

and more recently to RAL Services Cross Section Drawings

AO-TB-0049-166-00-D  è AO-TB-0049-170-00-D (last rev 02.11.00)

 

This note is intended as an aid to the calculation of pressure drops in the coolant distribution system between the evaporative cooling system flow control regulators, and the evaporation pressure-defining regulators. The regulators and back-pressure regulators are to be situated on racks on the ATLAS service platform, roughly in the location of connections at PPB3. This latest version takes account of the new insert-able pixel system service routings. Certain tube lengths are different than in the previous version.

 

It is assumed that the flow control regulators will be pre-cooled either with liquid, or with counter-evaporated C3F8 fluid, and that the C3F8 liquid destined for the evaporative cooling of the SCT and pixel modules will arrive in the region of PPB1 at a temperature around –20°C.

 

The circuit tubing is divided into nine zones as follows:

 

(1)   Liquid Supply Outside Magnet (pre-cooled to –20°C)

(2)   Liquid Supply: PPB/F3 è PPB/F2 (pre-cooled to –20°C)

(3)   Liquid Supply: PPB/F2 è PPB/F1 (pre-cooled to –20°C)

(4)   Liquid Supply: PPB/F1 è detectors (pre-cooled to –20°C)

(5)   On-detector evaporation zone (not considered here)

(6)   Vapor return  detectors è PPB/F1

(length = 0.5 - 2 m: partly within thermal shields)

(7)   Vapor Return: PPB/F1 è PPB/F2

(tube bundle insulation surface temperature  above local dewpoint)

(8)   Vapor Return: PPB/F2 è PPB/F3 (length = 12 m) [was 20m: change]

(tube bundle insulation surface temperature  above local dewpoint)

(9)   Vapor Return Outside Magnet (length = 12 m)

      (tube bundle insulation surface temperature  above local dewpoint)

 

 

Note that all bundles are subject to change. There has already been a reduction in the number of cooling channels for the pixel detector, which is not yest reflected in the drawings of the above reference.

 

Mass flow rates are based on an effective enthalpy of ~90 J/gm for C3F8 evaporating around – 25°C. A pre-cooling temperature of –20°C is inserted as a target.


(1)            SCT Barrel

 

Summary: Number of Cooling Channels, Channel Flow Rates, Coolant temperature.

Tube diameter and length in various Parts of the Cooling Circuits.

 

SCT Barrel Layer

6

5

4

3

No.  structures to cool

14

12

10

8

No.  Liquid Inputs

28

24

20

16

No. Vapor Returns

14

12

10

8

Power / Liquid Input (W)

240

240

240

240

Power / Vapor Exhaust (W)

480

480

480

480

Flow rate per liquid supply (gs-1)

2.7

2.7

2.7

2.7

Liq. Tube Inner Diameter

Zone (1): (mm) @ -20°C

l = 12m

3

3

3

3

Liq. Tube Diameter,

Zone (2): (mm) @ -20°C

L = 12 m PPB2èPPB3

3

3

3

3

Liq. Tube Diameter,

Zone (3) (mm) @ -20°C

L = 5.5 m PPB1èPPB2

3

3

3

3

Liq. Tube Diameter,

Zone (4): (mm) @ -20°C l= 0.86 m (capillary: Therm Encè PPB1

1

1

1

1

Liq. Tube Diameter,

Zone (4): (mm) @ -20°C l = 0.35m (capillary inside thermal enc.)

1

1

1

1

Liquid cooling tracer line diameter (mm) @ -20°C

flow rate not known, maybe evap

6

6

6

6

Flow rate per vapor return (gs-1)

5.4

5.4

5.4

5.4

Vap.Tube Diameter,

Zone (6) (mm) l = 0.35 m

(inside thermal vol)

5

5

5

5

Vap.Tube Diameter,

Zone (6) (mm) l = 0.86 m

Therm Encè PPB1

7

7

7

7

Vap. Tube Diameter,

Zone (7) (mm) l = 5.5 m PPB1èPPB2

10

10

10

10

Vap. Tube Diameter,

Zone (8) (mm) l = 12 m PPB2èPPB3

15

15

15

15

Vap. Tube Diameter,

Zone (9): (mm) l = 12 m

15

15

15

15

(2) SCT Disks

 

Summary: Number of Cooling Channels, Channel Flow Rates, Coolant temperature.

Tube diameter and length in various Parts of the Cooling Circuits.

 

Disk Type

A

B

No Disks

14

4

No.  structures to cool/disk

4

4

No.  Liquid Inputs/disk

12

4

No. Vapor Returns/disk

4

4

Total No Liquid Inputs

168

16

Total No Vapor Returns

56

16

Power per Liquid Input (W)

130 or 100

100

Power per Vapor Exhaust (W)

360

100

Flow rate per liquid supply (gs-1)

1.44 or 1.11

1.11

Liq. Tube Inner Diameter,

Zone (1): (mm) @ -20°C, l =12m

3

3

Liq. Tube Diameter,

Zone (2): (mm) @ -20°C, l =12m

2

2

Liq. Tube Diameter,

Zone (3) (mm) @ -20°C, l =2.8 m

2

2

Liq. Tube Diameter,

Zone (4): (mm) @ -20°C, l =1.5 m

2

2

Liq. Tube Diameter,

Zone (4): (mm) @ -20°C, l =1.5 m

(Assumes capillary)

1

1

Liquid cooling tracer diam(mm) @ -20°C

(flow rate not yet known, maybe evap)

6

6

Flow rate per vapor return (gs-1)

4

1.11

Vap.Tube Diameter,

Zone (6) (mm), l =1.5 m

(inside thermal vol)

5

5

Vap.Tube Diameter,

Zone (6) (mm), l =1.5 m

6

6

Vap. Tube Diameter,

Zone (7) (mm), l =2.8 m

8

8

Vap. Tube Diameter,

Zone (8) (mm) l =12m

11

11

Vap. Tube Diameter,

Zone (9): (mm) l =12m

11

11

 

(3)            Pixel Barrels 2,1

 

Summary: Number of Cooling Channels, Channel Flow Rates, Coolant temperature.

Tube diameter and length in various Parts of the Cooling Circuits.

 

Pixel Barrel Layer

2

1

No.  structures to cool

56

42

No.  Liquid Inputs

28

21

No. Vapor Returns

28

21

Power per Liquid Input (W)

216

216

Power per Vapor Exhaust (W)

216

216

Flow rate per liquid supply (gs-1)

2.4

2.4

Liq. Tube Inner Diameter,

Zone (1): (mm) @ -20°C,

L=100m (should be 12 m)

4

4

Liq. Tube Diameter,

Zone (2): (mm) @ -20°C, L = 14 m

PPB2 – PPB3

4

4

Liq. Tube Diameter,

Zone (3) (mm) @ -20°C, PPB2-PPF1

PPF1 – PPB 2 L = 2.5 m

 

 

3

 

 

3

Liq. Tube Diameter,

Zone (3) (mm) @ -20°C, PPB2-PPF1

Thermal Enc è PPF1, L = 2.6 m

 

 

2

 

 

2

Liq. Tube Diameter,

Zone (4): (mm) @ -20°C,

Inside Therm Enc, L = 0.5m, capillary

 

 

1

 

 

1

Liquid cooling tracer line diameter (mm) @ -20°C

(flow rate not yet known)

6

6

Flow rate per vapor return (gs-1)

2.4

2.4

Vap.Tube Diameter, Zone (6) (mm),

Inside Therm Enc, L = 0.5m

 

7

 

7

Vap. Tube Diameter, Zone (7) (mm),

Thermal Enc è PPF1, L = 2.6 m

 

7

 

7

Vap. Tube Diameter, Zone (7) (mm),

PPF1- PPB2; L 1 = 2.5 m

7

7

Vap. Tube Diameter, Zone (8) (mm),

PPB2 – PPB3

10

10

Vap. Tube Diameter, Zone (9): (mm),

L = 100m (should be 12 m)

10

10

(4)             Pixel B layer

 

Summary: Number of Cooling Channels, Channel Flow Rates, Coolant temperature.

Tube diameter and length in various Parts of the Cooling Circuits.

 

Pixel B Layer

 

No.  structures to cool

12

No.  Liquid Inputs

12

No. Vapor Returns

12

Power per Liquid Input (W)

240

Power per Vapor Exhaust (W)

240

Flow rate per liquid supply (gs-1)

2.7

Liq. Tube Inner Diameter,

Zone (1): (mm) @ -20°C L = 100m (should be 12 m)

4

Liq. Tube Diameter,

Zone (2): (mm) @ -20°C, L = 20 m PPF2è PPF3

4

Liq. Tube Diameter,

Zone (3) (mm) @ -20°C,

L = 2.5 m; PPF1 è PPB2

3

Liq. Tube Diameter,

Zone (4): (mm) @ -20°C, L = 2.1 m;

Thermal  Enclosure è PPF1

3

Liq. Tube Diameter,

Zone (4): (mm) @ -20°C,

L = 0.5 Inside Therm. Enc (capillary)

1

Liquid cooling tracer line diameter (mm)

@ -20°C (flow rate not yet known)

6

Flow rate per vapor return (gs-1)

2.7

Vap.Tube Diameter,

Zone (6) (mm), L = 0.5 m; 

Inside  Thermal Enclosure

8

Vap.Tube Diameter,

Zone (6) (mm), L = 2.1 m; 

Therm. Enc è PPF1

8

Vap. Tube Diameter,

Zone (7) (mm), L = 2.5 m;  PPF1 è PPB2

8

Vap. Tube Diameter,

Zone (8) (mm), L = 20 m PPF2è PPF3

12

Vap. Tube Diameter,

Zone (9): (mm) L = 100m (should be 12 m)

12

 

(5)            Pixel End Caps

 

Summary: Number of Cooling Channels, Channel Flow Rates, Coolant temperature.

Tube diameter and length in various Parts of the Cooling Circuits.

 

No Disks

10

No.  structures to cool/disk

6

No.  Liquid Inputs/disk

6

No. Vapor Returns/disk

6

Total No Liquid Inputs

60

Total No Vapor Returns

60

Power per Liquid Input (W)

90

Power per Vapor Exhaust (W)

90

Flow rate per liquid supply (gs-1)

1

Liq. Tube Inner Diameter,

Zone (1): (mm) @ -20°C, l = 12 m

4

Liq. Tube Diameter,

Zone (2): (mm) @ -20°C, l = 14 m  PPB2èPPB3

4

Liq. Tube Diameter,

Zone (3) (mm) @ -20°C, l =2.5 m PPF1èPPB2

2

Liq. Tube Diameter,

Zone (4): (mm) @ -20°C, l = 2.6 m

Thermal Enclosure è PPF1

 

 

2

Liq. Tube Diameter,

Zone (4): (mm) @ -20°C, l =0.3 m

Inside Thermal Enclosure (capillary)

 

 

1

Liquid cooling tracer line diameter (mm) @ -20°C

6

Flow rate per vapor return (gs-1)

1

Vap.Tube Diameter,

Zone (6) (mm); L1 = 0.3 m  Inside Thermal Enclosure

6

Vap.Tube Diameter,

Zone (6) (mm); L1 = 1 m, L2 = 2.6 m;

Thermal Enclosure è PPF1

 

 

6

Vap. Tube Diameter,

Zone (7) (mm) l = 2.5 m PPF1èPPB2

6

Vap. Tube Diameter,

Zone (8) (mm), l = 14 m; PPB2èPPB3

8

Vap. Tube Diameter,

Zone (9): (mm); L = 12 m

8

 


(6)           Phase 2 Demonstrator: SCT layers 6,5,4&3

 

Summary: Number of Cooling Channels, Channel Flow Rates, Coolant temperature.

Tube diameter and length in various Parts of the Cooling Circuits.

SCT Barrel Layer

6

5

4

3

Tube choice

No.  structures to cool

2

2

1

1

-

No.  Liquid Inputs

4

4

2

2

-

No. Vapor Returns

2

2

1

1

-

Power / Liquid Input (W)

240

240

240

240

-

Power / Vapor Exhaust (W)

480

480

480

480

-

Flow rate per liquid supply (gs-1)

2.7

2.7

2.7

2.7

-

Liq. Tube Inner Diameter

Zone (1): (mm) @ -20°C

l = 12m

3

3

3

3

5/3

Liq. Tube Diameter,

Zone (2): (mm) @ -20°C

L = 12 m PPB2èPPB3

3

3

3

3

5/3

Liq. Tube Diameter,

Zone (3) (mm) @ -20°C

L = 5.5 m PPB1èPPB2

3

3

3

3

5/3

Liq. Tube Diameter,

Zone (4): (mm) @ -20°C l= 0.86 m (capillary: Therm Encè PPB1

1

1

1

1

0.8 mm Cap

Liq. Tube Diameter,

Zone (4): (mm) @ -20°C l = 0.35m (capillary inside thermal enc.)

1

1

1

1

0.8 mm Cap

Liquid cooling tracer line diameter (mm) @ -20°C

flow rate not known, maybe evap

6

6

6

6

6/8

Flow rate per vapor return (gs-1)

5.4

5.4

5.4

5.4

-

Vap.Tube Diameter,

Zone (6) (mm) l = 0.35 m

(inside thermal vol)

5

5

5

5

8/6

Vap.Tube Diameter,

Zone (6) (mm) l = 0.86 m

Therm Encè PPB1

7

7

7

7

10/8

Vap. Tube Diameter,

Zone (7) (mm) l = 5.5 m PPB1èPPB2

10

10

10

10

12/10

Vap. Tube Diameter,

Zone (8) (mm) l = 12 m PPB2èPPB3

15

15

15

15

16/14

Vap. Tube Diameter,

Zone (9): (mm) l = 12 m

15

15

15

15

16/14

(7) Phase 2 Demonstrator: Pixel Barrel 2,1

 

Summary: Number of Cooling Channels, Channel Flow Rates, Coolant temperature.

Tube diameter and length in various Parts of the Cooling Circuits.

Pixel Barrel Layer

2

1

Tube choice

No.  structures to cool

4

3

-

No.  Liquid Inputs

4

3

-

No. Vapor Returns

4

3

-

Power per Liquid Input (W)

216

216

-

Power per Vapor Exhaust (W)

216

216

-

Flow rate per liquid supply (gs-1)

2.4

2.4

-

Liq. Tube Inner Diameter,

Zone (1): (mm) @ -20°C,

L=100m (should be 12 m)

4

4

6/4

Liq. Tube Diameter,

Zone (2): (mm) @ -20°C, L = 14 m

PPB2 – PPB3

4

4

6/4

Liq. Tube Diameter,

Zone (3) (mm) @ -20°C, PPB2-PPF1

PPF1 – PPB 2 L = 2.5 m

 

 

3

 

 

3

 

 

6/4

Liq. Tube Diameter,

Zone (3) (mm) @ -20°C, PPB2-PPF1

Thermal Enc è PPF1, L = 2.6 m

 

 

2

 

 

2

 

 

4/2

Liq. Tube Diameter,

Zone (4): (mm) @ -20°C,

Inside Therm Enc, L = 0.5m, capillary

 

 

1

 

 

1

 

 

0.8 mm Cap

Liquid cooling tracer line diameter (mm) @ -20°C (flow rate not yet known)

6

6

8/6

Flow rate per vapor return (gs-1)

2.4

2.4

-

Vap.Tube Diameter, Zone (6) (mm),

Inside Therm Enc, L = 0.5m

 

7

 

7

 

10/8

Vap. Tube Diameter, Zone (7) (mm),

Thermal Enc è PPF1, L = 2.6 m

 

7

 

7

 

10/8

Vap. Tube Diameter, Zone (7) (mm),

PPF1- PPB2; L 1 = 2.5 m

7

7

10/8

Vap. Tube Diameter, Zone (8) (mm),

PPB2 – PPB3

10

10

12/10

Vap. Tube Diameter, Zone (9): (mm),

L = 100m (should be 12 m)

10

10

12/10

 

(8) Phase 2  Demonstrator: Pixel B layer

 

Summary: Number of Cooling Channels, Channel Flow Rates, Coolant temperature.

Tube diameter and length in various Parts of the Cooling Circuits.

Pixel B Layer

 

Tube Choice

No.  structures to cool

2

-

No.  Liquid Inputs

2

-

No. Vapor Returns

2

-

Power per Liquid Input (W)

280

-

Power per Vapor Exhaust (W)

280

-

Flow rate per liquid supply (gs-1)

3.1

-

Liq. Tube Inner Diameter,

Zone (1): (mm) @ -20°C L = 100m (should be 12 m)

4

6/4

Liq. Tube Diameter,

Zone (2): (mm) @ -20°C, L = 20 m PPF2è PPF3

4

6/4

Liq. Tube Diameter,

Zone (3) (mm) @ -20°C,

L = 2.5 m; PPF1 è PPB2

3

5/3

Liq. Tube Diameter,

Zone (4): (mm) @ -20°C, L = 2.1 m;

Thermal  Enclosure è PPF1

3

5/3

Liq. Tube Diameter,

Zone (4): (mm) @ -20°C,

L = 0.5 Inside Therm. Enc (capillary)

1

0.8 Cap

Liquid cooling tracer line diameter (mm)

@ -20°C (flow rate not yet known)

6

6/8

Flow rate per vapor return (gs-1)

3.1

-

Vap.Tube Diameter,

Zone (6) (mm), L = 0.5 m; 

Inside  Thermal Enclosure

8

10/8

Vap.Tube Diameter,

Zone (6) (mm), L = 2.1 m; 

Therm. Enc è PPF1

8

10/8

Vap. Tube Diameter,

Zone (7) (mm), L = 2.5 m;  PPF1 è PPB2

8

10/8

Vap. Tube Diameter,

Zone (8) (mm), L = 20 m PPF2è PPF3

12

14/12

Vap. Tube Diameter,

Zone (9): (mm) L = 100m (should be 12 m)

12

14/12

 

 


(9) Phase 2 Demonstrator: SCT End Caps

 

Summary: Number of Cooling Channels, Channel Flow Rates, Coolant temperature.

Tube diameter and length in various Parts of the Cooling Circuits.

Disk Type

A

Tube Choice

No Disks

1/4

-

No.  structures to cool/disk

1

-

No.  Liquid Inputs/disk

3

-

No. Vapor Returns/disk

1

-

Total No Liquid Inputs

3

-

Total No Vapor Returns

1

-

Power per Liquid Input (W)

130 or 100

-

Power per Vapor Exhaust (W)

360

-

Flow rate per liquid supply (gs-1)

1.44 or 1.11

-

Liq. Tube Inner Diameter,

Zone (1): (mm) @ -20°C, l =12m

3

5/3

Liq. Tube Diameter,

Zone (2): (mm) @ -20°C, l =12m

2

4/2

Liq. Tube Diameter,

Zone (3) (mm) @ -20°C, l =2.8 m

2

4/2

Liq. Tube Diameter,

Zone (4): (mm) @ -20°C, l =1.5 m

2

4/2

Liq. Tube Diameter,

Zone (4): (mm) @ -20°C, l =1.5 m

(Assumes capillary)

1

0.8 Cap

Liquid cooling tracer diam(mm) @ -20°C

(flow rate not yet known, maybe evap)

6

8/6

Flow rate per vapor return (gs-1)

4

-

Vap.Tube Diameter,

Zone (6) (mm), l =1.5 m

(inside thermal vol)

5

8/6

Vap.Tube Diameter,

Zone (6) (mm), l =1.5 m

6

8/6

Vap. Tube Diameter,

Zone (7) (mm), l =2.8 m

8

10/8

Vap. Tube Diameter,

Zone (8) (mm) l =12m

11

12/10

Vap. Tube Diameter,

Zone (9): (mm) l =12m

11

12/10


(10) Phase 2 Demonstrator: Pixel End Caps

 

Summary: Number of Cooling Channels, Channel Flow Rates, Coolant temperature.

Tube diameter and length in various Parts of the Cooling Circuits.

No.  structures to cool

1

Tube Choice

Total No Liquid Inputs

1

-

Total No Vapor Returns

1

-

Power per Liquid Input (W)

90

-

Power per Vapor Exhaust (W)

90

-

Flow rate per liquid supply (gs-1)

1

-

Liq. Tube Inner Diameter,

Zone (1): (mm) @ -20°C, l = 12 m

4

6/4

Liq. Tube Diameter,

Zone (2): (mm) @ -20°C, l = 14 m  PPB2èPPB3

4

6/4

Liq. Tube Diameter,

Zone (3) (mm) @ -20°C, l =2.5 m PPF1èPPB2

2

3/2

Liq. Tube Diameter,

Zone (4): (mm) @ -20°C, l = 2.6 m

Thermal Enclosure è PPF1

 

 

2

3/2

Liq. Tube Diameter,

Zone (4): (mm) @ -20°C, l =0.3 m

Inside Thermal Enclosure (capillary)

 

 

1

0.8 Cap

Liquid cooling tracer line diameter (mm) @ -20°C

6

8/6

Flow rate per vapor return (gs-1)

1

-

Vap.Tube Diameter,

Zone (6) (mm); L1 = 0.3 m  Inside Thermal Enclosure

6

8/6

Vap.Tube Diameter,

Zone (6) (mm); L1 = 1 m, L2 = 2.6 m;

Thermal Enclosure è PPF1

 

 

6

8/6

Vap. Tube Diameter,

Zone (7) (mm) l = 2.5 m PPF1èPPB2

6

8/6

Vap. Tube Diameter,

Zone (8) (mm), l = 14 m; PPB2èPPB3

8

10/8

Vap. Tube Diameter,

Zone (9): (mm); L = 12 m

8

10/8

 

 

 


(C) Tube Bundle Requirements for Phase (2) Demonstrator

 

This is based on the number of tubes accommodated in each type of tube bundle proposed by Andy Nichols in the most recent service diagrams.

 

(1)   SCT Barrel

 

Structure Tube I/O requirement

No C3F8 Inputs

No C3F8 Outputs

12

6

 

Bundle Configuration in A0-TB-0049-169-00D (18.09.2000)

 

Input Bundle

No C3F8 liquid tubes

No precooling Tubes

6

2

 

Output Bundle

No C3F8 vapor tubes

No precooling Tubes

6

0

 

Requirement

 

2 x input bundles,

1 x output bundle (tube diameter progressive variation as in table (6).         

 

Flow Regs: 12:                   Backpressure Regs:                         6

 

(2) Pixel Barrel, layers 1 & 2,

 

Structure Tube I/O requirement

No C3F8 Inputs

No C3F8 Outputs

6*

6*

 

·        Note: this is less than in the original Phase 2 proposal, but since then, the numbers of pixel staves has reduced for an insertable layout. Also 6 tubes fits better the present tube bundle modularity.

 

Bundle Configuration in A0-TB-0049-166-00D (02.11.2000)

 

Input Bundle

No C3F8 liquid tubes

No precooling Tubes

6

2

 

Output Bundle

No C3F8 vapor tubes

No precooling Tubes

2

0

 

Requirement

 

1 x input bundles,

bundle (tube diameter progressive variation as in table (7))

 

Flow Regs: 6:                     Backpressure Regs:                         6

(3) Pixel B Layer

 

Structure Tube I/O requirement

No C3F8 Inputs

No C3F8 Outputs

1

1

 

Bundle Configuration in A0-TB-0049-167-00D (03.11.2000)

 

Input Bundle

No C3F8 liquid tubes

No precooling Tubes

3

2

 

Output Bundle

No C3F8 vapor tubes

No precooling Tubes

3

0

 

Requirement

 

1 x input bundle,

1 x output bundle (tube diameter progressive variation as in table (8).

 

Note: Though only one tube of three is used in the first stage, it is probably worth building this         

bundle.  It might also serve later for tests of structures.

 

Flow Regs: 1:                     Backpressure Regs:                          1         

 

(4) Forward SCT

 

Structure Tube I/O requirement

No C3F8 Inputs

No C3F8 Outputs

3

1

 

Bundle Configuration in A0-TB-0049-170-00D (09.11.2000)

 

Input Bundle

No C3F8 liquid tubes

No precooling Tubes

22

2

 

Output Bundle

No C3F8 vapor tubes

No precooling Tubes

9

0

 

Requirement

 

Suggest one extra pixel B layer bundle pair (as in (3) above) is made for forward

SCT  structure tests.

 

Flow Regs: 3:                     Backpressure Regs:                         1

 


(5) Pixel Disks

 

Structure Tube I/O requirement

No C3F8 Inputs

No C3F8 Outputs

1

1

 

Bundle Configuration in A0-TB-0049-168-00D (03.11.2000)

 

Input Bundle: Type (1)

No C3F8 liquid tubes

No precooling Tubes

6

2

 

 

Input Bundle: Type (2)

No C3F8 liquid tubes

No precooling Tubes

3

0

 

Output Bundle: Type (1)

No C3F8 vapor tubes

No precooling Tubes

7

2

 

Output Bundle: Type (2)

No C3F8 vapor tubes

No precooling Tubes

4

0

 

Requirement

 

Suggest using spare tubes in B layer bundle (as in (3) above). 

 

Flow Regs: 1:                     Backpressure Regs:                         1

 

Regulator Total (1) è (5)

 

 

Flow Regs: 23:                   Backpressure Regs:                         15

 

Other Regulator Requirements

 

          Structure Testing

 

Flow Regs: 1:                     Backpressure Regs:                         1

 

            C3F8 Liquid Precooling

 

Flow Regs: 1:                     Backpressure Regs:                         1

 

          Line Cooling

 

Flow Regs: 1:                     Backpressure Regs:                         1

 

Regulator  Grand Total

 

Flow Regs: 26:                   Backpressure Regs:                         18